Notice

General Information

Tokyo Mou - PSC inspection summary of 2017.3.1-3.31

 

 Summary of 2017.3.1-3.31

Authority:

AUSTRALIA

 

Typical deficiency :

NO.1

Code:

07115      Fire-dampers

Detail:

Engine Room fan fire damper starboard side defective.(30)(Actuator leaking oil, indicator failed to move fully - high airflow through fan when damper is in closed position.STBD fan dampers open position - crew unable to demonstrate external operation.)

NO.2

Code:

18418     Winches & capstan

Detail:

Safety pins is not in position on winches.

NO.3

Code:

05114 reserve source of energy

Detail:

GMDSS batteries defective(30)

NO.4

Code:

07199     Other (fire safety)

Detail:

Both gas meters used for sampling atmosphere of cargo holds defective. Both are indicating LEL of -7%. Vessel is carrying a cargo of coal.

 

 

Authority:

Russia

 

Typical deficiency :

NO.1

Code:

14703     Paint condition

Detail:

AFS- not satisfactory condition

NO.2

Code:

14104 oil filtering equipment

Detail:

Connection pipe between solenoid valve and drain system not satisfactory  condition.

NO.3

Code:

09205     Safe means of access Shore - Ship

Detail:

Passage from shore to ship not safety. gangway not equipped properly. safety net missing

NO.4

Code:

18416     Ropes and wires

Detail:

Mooring ropes (3 pcs) - in very bad condition

NO.5

Code:

10109     Lights, shapes, sound-signals

Detail:

Navigation lights (aft and port side) are not fixed

 

 

 

 

Authority:

China

 

Typical deficiency :

NO.1

Code:

06107     Cargo operation

Detail:

The ship/shore safety checklist (16-mar-2017)in consultation with the terminal not completed before unloading is commenced as the requirement of res. a.862(20).

NO.2

Code:

09131 cold room

Detail:

Lots of ice accumulation near the drainage in the meat room

NO.3

Code:

10104     Gyro compass

Detail:

Magnetic compass not clearly readable by helmsman at the main steering position when supplied by dc power.

NO.4

Code:

07122     Fire control plan

Detail:

Location sign for the enclosure of fire control plan not posted correctly

 

 

Authority:

Japan

 

Typical deficiency :

NO.1

Code:

07103     Division - decks, bulkheads and penetrations

Detail:

Cable penetration between stairway and bridge - not insulated properly(lack of compound)

NO.2

Code:

11125      Embarkation arrangements rescue boats

Detail:

Access to port side life boat (rescue boat) - not accessed immediately due to obstacle

NO.3

Code:

06107 crgo operation

Detail:

A container at 26.06.02 - not secured properly

NO.4

Code:

01328     Ship Energy Efficiency Management plan

Detail:

Ship energy efficiency management plan not up dated

 


List