Tokyo Mou - PSC inspection summary of 2017.3.1-3.31
|
|
Summary of 2017.3.1-3.31 | ||
|
Authority: |
AUSTRALIA |
| |
|
Typical deficiency : | |||
|
NO.1 |
Code: |
07115 Fire-dampers | |
|
Detail: |
Engine Room fan fire damper starboard side defective.(30)(Actuator leaking oil, indicator failed to move fully - high airflow through fan when damper is in closed position.STBD fan dampers open position - crew unable to demonstrate external operation.) | ||
|
NO.2 |
Code: |
18418 Winches & capstan | |
|
Detail: |
Safety pins is not in position on winches. | ||
|
NO.3 |
Code: |
05114 reserve source of energy | |
|
Detail: |
GMDSS batteries defective(30) | ||
|
NO.4 |
Code: |
07199 Other (fire safety) | |
|
Detail: |
Both gas meters used for sampling atmosphere of cargo holds defective. Both are indicating LEL of -7%. Vessel is carrying a cargo of coal. | ||
|
|
| ||
|
Authority: |
Russia |
| |
|
Typical deficiency : | |||
|
NO.1 |
Code: |
14703 Paint condition | |
|
Detail: |
AFS- not satisfactory condition | ||
|
NO.2 |
Code: |
14104 oil filtering equipment | |
|
Detail: |
Connection pipe between solenoid valve and drain system not satisfactory condition. | ||
|
NO.3 |
Code: |
09205 Safe means of access Shore - Ship | |
|
Detail: |
| ||
|
NO.4 |
Code: |
18416 Ropes and wires | |
|
Detail: |
Mooring ropes (3 pcs) - in very bad condition | ||
|
NO.5 |
Code: |
10109 Lights, shapes, sound-signals | |
|
Detail: |
Navigation lights (aft and port side) are not fixed | ||
|
|
|
|
|
|
Authority: |
China |
| |
|
Typical deficiency : | |||
|
NO.1 |
Code: |
06107 Cargo operation | |
|
Detail: |
The ship/shore safety checklist (16-mar-2017)in consultation with the terminal not completed before unloading is commenced as the requirement of res. a.862(20). | ||
|
NO.2 |
Code: |
09131 cold room | |
|
Detail: |
Lots of ice accumulation near the drainage in the meat room | ||
|
NO.3 |
Code: |
10104 Gyro compass | |
|
Detail: |
Magnetic compass not clearly readable by helmsman at the main steering position when supplied by dc power. | ||
|
NO.4 |
Code: |
07122 Fire control plan | |
|
Detail: |
Location sign for the enclosure of fire control plan not posted correctly | ||
|
|
| ||
|
Authority: |
Japan |
| |
|
Typical deficiency : | |||
|
NO.1 |
Code: |
07103 Division - decks, bulkheads and penetrations | |
|
Detail: |
| ||
|
NO.2 |
Code: |
11125 Embarkation arrangements rescue boats | |
|
Detail: |
| ||
|
NO.3 |
Code: |
06107 crgo operation | |
|
Detail: |
A container at 26.06.02 - not secured properly | ||
|
NO.4 |
Code: |
01328 Ship Energy Efficiency Management plan | |
|
Detail: |
Ship energy efficiency management plan not up dated | ||
| |||