Summary of 2017.4.29-5.15
| |
Authority:
|
AUSTRALIA
|
Inspected Vessels
|
152
|
Detained Vessels
|
5
| |
Typical
deficiency :
| |
NO.1
|
Code:
|
03108
Ventilators, air pipes, casings
| |
Detail:
|
Ballast tank air
vents defective. (Many places including critical locations).
| |
NO.2
|
Code:
|
10101
Pilot ladders and hoist/pilot transfer arrangements
| |
Detail:
|
Pilot Ladder wires
defective. Port side pilot assist ladder wire parted on arrival in Weipa.
Pilot ladder not rigged per SOLAS V/23 and IMO Res A.1045(27)
| |
| | | | | |
| |
Authority:
|
China
|
Inspected Vessels
|
245
|
Detained Vessels
|
12
| |
Typical
deficiency :
| |
NO.1
|
Code:
|
11117
Lifebuoys incl. provision and disposition
| |
Detail:
|
No lifebuoy equipped
with a self-igniting light and a buoyant lifeline found nearby when the
accommodation ladder of port side in use in yangshan port
| |
NO.2
|
Code:
|
11117
Lifebuoys incl. provision and disposition
| |
Detail:
|
Rescue boat
davit: hydraulic release system defective (one hydraulic pipe valve rusted
and leaked seriously)
| |
| | | | | |
| |
Authority:
|
Japan
|
Inspected Vessels
|
127
|
Detained Vessels
|
2
| |
Typical
deficiency :
| |
NO.1
|
Code:
|
01126
Document of Compliance Dangerous Goods
| |
Detail:
|
Document of
compliance with special requirements for ships carrying dangerous goods,
stowage space of D.G.cargo was not described correctly ("d1 (forward of
the ACCOM.)"only was allowed to stow D.G.cargoes,but there was no space
to stow D.G.cargoes in forward CF the ACCOM.)
| |
NO.2
|
Code:
|
03199
Other (load lines)
| |
Detail:
|
Opening on enclosure
bulkhead on exposed "a" deck to cargo hold nearby doorway - no
closure provided
| |
| | | | | |
| |
Authority:
|
Russia
|
Inspected Vessels
|
39
|
Detained Vessels
|
1
| |
Typical
deficiency :
| |
NO.1
|
Code:
|
07110
Fire fighting equipment and appliances
| |
Detail:
|
Two portable fire
extinguishers - rubber hoses worn out
| |
NO.2
|
Code:
|
11112
Launching arrangements for survival craft
| |
Detail:
|
Wire lifting sling
for free fall lifeboat are coved in plastic sheathing and not easily
accessible for inspection or maintenance
| |