Summary of 2017.4.1-4.28
|
Authority:
|
AUSTRALIA
|
Inspected Vessels
|
178
|
Detained Vessels
|
6
|
Typical
deficiency :
|
NO.1
|
Code:
|
04114
Emergency source of power - Emergency generator
|
Detail:
|
Emergency generator
defective(owing no power 60
seconds after EMDG started.)
|
NO.2
|
Code:
|
14104
Oil filtering equipment
|
Detail:
|
Oily water separator
is inoperable due to broken priming line valve for the suction pump. Pump
unable to take suction without priming.
|
NO.3
|
Code:
|
03104 Cargo &
other hatchways
|
Detail:
|
Several hatch cover
cleat supports corroded by No 4 and 5 hold
|
NO.4
|
Code:
|
18314
Provisions quantity
|
Detail:
|
Insufficient fresh
vegetables to last until next intended storing point.
|
| | | | | |
|
Authority:
|
China
|
Inspected Vessels
|
452
|
Detained Vessels
|
16
|
Typical
deficiency :
|
NO.1
|
Code:
|
02106
Hull damage impairing seaworthiness
|
Detail:
|
Bulbous deformed and
holed near the waterline due to the collision and the damage not reported to
the port authority before entering the port.
|
NO.2
|
Code:
|
11101
Lifeboats
|
Detail:
|
The oars of P& S
side lifeboat broken
|
NO.3
|
Code:
|
14104
Oil filtering equipment
|
Detail:
|
Oil discharging
solenoid valve of oily water separator out of order
|
NO.4
|
Code:
|
13103
Gauges,thermometers, etc
|
Detail:
|
One pressure gauge
for eductor suction of ballast stripping damaged.
|
| | | | | |
|
Authority:
|
Japan
|
Inspected Vessels
|
411
|
Detained Vessels
|
2
|
Typical
deficiency :
|
NO.1
|
Code:
|
03104
Cargo & other hatchways
|
Detail:
|
Hatch cover of tunnel
on up deck near fr.91(p-side) - gapped
|
NO.2
|
Code:
|
03104
Cargo & other hatchways
|
Detail:
|
Cap of gas sampling
point on coaming of c/h (s-side) - missing.
|
NO.3
|
Code:
|
13199
Other (machinery)
|
Detail:
|
Oil mist detector for
main propulsion engine - indicated trouble alarm
|
NO.4
|
Code:
|
14599
Other MARPOL Annex V
|
Detail:
|
cargo residue of the
last voyage - left on exposure deck(granulate matter as the last cargo,urea was left on there)
|
| | | | | |
|
Authority:
|
Russia
|
Inspected Vessels
|
88
|
Detained Vessels
|
6
|
Typical
deficiency :
|
NO.1
|
Code:
|
18408
Electrical
|
Detail:
|
Non conducting mat at
front main switchboard in engine in engine room -poor condition
|
NO.2
|
Code:
|
04103
Emergency, lighting,batteries and switche
|
Detail:
|
Rubber hose of
cooling system for emergency diesel generator in poor condition
|
NO.3
|
Code:
|
07108
Ready availability of fire fighting equipment
|
Detail:
|
Fire foam
applicators(4pcs) in e/r - broken and empty
|
NO.4
|
Code:
|
14402 Sewage
treatment plant
|
Detail:
|
Pressure gauge of
sewage treatment plant -broken
|